Level Instrument Leading Service Provider of endress cngmass dci coriolis flowmeter, endress cngmass coriolis flowmeter, endress hydrostatic level measurement waterpilot fmx11, endress conductive point level detection sensor liquipoint ftw33 and endress lngmass coriolis flowmeter from Ahmedabad.
Endress CNGmass DCI Coriolis flowmeter Approx. Price: Rs 11,20,356 / Piece Get Latest Price
View Brochure Service Details:
Fluid Type Gas Mass Flow Range 0–1000 kg/hr Line Size 6 mm Accuracy ±0.2% Output Signal Pulse, 4–20 mA Density Output No Tube Material Titanium Power Supply 24 V DC
Max. measurement errorMass flow: ±0.5 % of batchMeasuring range0 to 150 kg/min (0 to 330 lb/min)Max. process pressure350 bar (5080 psi)Medium temperature range–50 to +150 °C (–58 to +302 °F)Ambient temperature rangeStandard: –20 to +60 °C (–4 to +140 °F)Option: –40 to +60 °C (–40 to +140 °F)Sensor housing material1.4301 (304), corrosion resistantTransmitter housing materialPowder‐coated die‐cast aluminium
Endress CNGmass Coriolis flowmeter Approx. Price: Rs 7,89,523 / Piece Get Latest Price
View Brochure Service Details:
Minimum Order Quantity 1 Piece Fluid Type Liquids Mass Flow Range 0 to 150 kg/min Line Size 6 mm Accuracy ±0.1% Output Signal Pulse Density Output Yes Tube Material Titanium Power Supply 24 V DC
Specs at a glance
Max. measurement error
Mass flow: ±0.5 % of batch
Measuring range
0 to 150 kg/min (0 to 330 lb/min)
Medium temperature range
–50 to +125 °C (–58 to +257 °F)
Max. process pressure
350 bar (5080 psi)
Wetted materials
Measuring tube: 1.4435 (316L) Connection: 1.4404 (316)
Additional Information:
Delivery Time: 6 to 8 weeks
Endress Hydrostatic Level measurement Waterpilot FMX11 Approx. Price: Rs 1,45,698 / Piece Get Latest Price
Service Details:
Minimum Order Quantity 1 Piece Measuring range 0 to 200 m Output signal 4 to 20 mA Wetted material SS316 Cable length 30 m Accuracy 0.35% Process connection Clamp Enclosure rating IP67 Temp range -10 to 60 C Supply voltage 12 to 30 V DC
Accuracy
pn ≥ 400mbar: 0.35 % pn < 400mbar: 0.50 %
Process temperature
-10°C...+70°C (+14°F...+158°F)
Pressure measuring range
200 mbar...2 bar (3 psi...29 psi)
Process pressure / max. overpressure limit
10 bar (145 psi)
Main wetted parts
316L
Max. measurement distance
20 m H2O (66 ft H2O)
Material process membrane
Metal
Measuring cell
200 mbar...2 bar (3 psi...29 psi)
Additional Information:
Delivery Time: 6 to 8 week
Endress Conductive Point level detection Sensor Liquipoint FTW33
Endress LNGmass Coriolis flowmeter