Service Details:
| Minimum Order Quantity | 1 Piece |
| Installation Type | Inline |
| Fluid Type | Water |
| Line Size Range | 25–100 mm |
| Display Type | LCD |
| Output Signal | 4–20 mA |
| Power Supply | 19.2 to 28.8 V |
| Accuracy | ±0.5% |
| Mounting | Portable |
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Promag H |
| Meter Technology | Ultrasonic |
| Fluid Type | Wastewater |
| Line Size | 80 mm |
| Accuracy | ±0.2% |
| Liner Material | PFA |
| Electrode Material | Platinum |
| Communication | HART |
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Prosonic |
| Meter Technology | Ultrasonic |
| Fluid Type | Gas |
| Output Signal | HART, 4–20 mA |
| Accuracy | ±0.5% |
| Liner Material | Polyurethane |
| Electrode Material | Tantalum |
| Communication | HART |
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.2 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.1 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±0.8 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r.
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Proline |
| Meter Technology | ultrasonic flowmeter |
| Fluid Type | Gas |
| Line Size | 150 mm |
| Output Signal | Modbus |
| Accuracy | ±0.1% |
| Liner Material | PFA |
| Electrode Material | Stainless Steel |
| Communication | Modbus TCP |
Volume a. c., volumetric flow a. c., gas velocity, volume s. c. (*), volume flow under s.c. (*)
(*) additional function included with integrated volume correction
Natural gas (dry, odorized), air
DN 50 (2") … DN 150 (6")
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Proline |
| Meter Technology | Ultrasonic |
| Fluid Type | Gas |
| Output Signal | Modbus, 4–20 mA, HART, Pulse |
| Accuracy | ±0.5% |
| Liner Material | Hard Rubber |
| Electrode Material | Stainless Steel |
| Communication | HART |
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Promag |
| Meter Technology | Electromagnetic |
| Fluid Type | Water |
| Line Size | 15 mm |
| Output Signal | HART, 4–20 mA |
| Accuracy | ±0.5% |
| Liner Material | PFA |
| Electrode Material | Hastelloy |
| Communication | PROFIBUS PA, HART |
Flow: ±5 % o.f.s.
226 to 14 100 000 l/h (60 to 3 730 000 gal/h)
(under reference conditions)
–20 to +100 °C (–4 to +212 °F)
PN 40
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Promass |
| Meter Technology | Differential Pressure |
| Fluid Type | Gas |
| Line Size | 80 mm |
| Output Signal | Pulse, 4–20 mA |
| Accuracy | ±0.2% |
| Liner Material | Hard Rubber |
| Electrode Material | Stainless Steel |
| Communication | HART |
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Fluid Type | Liquids |
| Mass Flow Range | 0 to 180 000 kg/h |
| Line Size | 50 mm |
| Accuracy | ±0.1% |
| Output Signal | HART, 4–20 mA |
| Tube Material | Titanium |
| Power Supply | 24 V DC |
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³
0 to 180 000 kg/h (0 to 6600 lb/min)
–50 to +150 °C (–58 to +302 °F)
PN 100, Class 600, 63K
Measuring tube: Titanium grade 9
Connection: Titanium grade 2
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Prowirl |
| Meter Technology | Vortex |
| Fluid Type | Gas, Oil, Steam |
| Line Size | 150 mm |
| Output Signal | HART, Pulse |
| Accuracy | ±0.5% |
| Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus, Modbus TCP |
Additional Information:
Service Details:
| Flow Meter Type | Inline |
Service Details:
| Minimum Order Quantity | 1 Piece |
| Fluid Type | Gas |
| Mass Flow Range | 70 000 |
| Line Size | 40 mm |
| Accuracy | ±0.2% |
| Output Signal | Pulse, HART, 4–20 mA |
| Density Output | Yes |
| Tube Material | Titanium |
| Power Supply | 24 V DC |
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Mass flow (gas, Tantalum only): ±0.50 %
Density (liquid): ±0.0005 g/cm³
0 to 70 000 kg/h (0 to 2570 lb/min)
Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F)
PN 40, Class 300, 20K
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Fluid Type | Liquids |
| Mass Flow Range | 0 to 180 000 kg/h |
| Line Size | 80 mm |
| Accuracy | ±0.1% |
| Output Signal | HART, 4–20 mA, Pulse |
| Tube Material | Titanium |
| Power Supply | 24 V DC |
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Fluid Type | Liquids |
| Mass Flow Range | 0–1000 kg/hr |
| Line Size | 6 mm |
| Accuracy | ±0.2% |
| Output Signal | Pulse |
| Density Output | No |
| Tube Material | Hastelloy C |
| Power Supply | 24 V DC |
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3
0 to 1000 kg/h (0 to 37 lb/min)
–50 to +200 °C (–58 to +392 °F)
PN 40, Class 300, 10K, 400 bar (5800 psi)
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Additional Information:
Service Details:
| Minimum Order Quantity | 3 Piece |
| Resolution | resolution - 0.01 m/s (depending on gas type and measuring range). |
| Material | Stainless Steel |
| Brand | Flowtech |
| Application Media | Water |
| Usage/Application | Automotive |
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | pressure |
| Meter Technology | Electromagnetic |
| Fluid Type | pressure |
| Output Signal | Profinet, Profibus, HART, 4–20 mA |
| Line Size | 100 mm |
| Accuracy | ±0.1% |
| Liner Material | Hard Rubber |
| Electrode Material | Platinum |
| Communication | PROFIBUS PA, HART, Profinet |
Standard:
up to 0.1 %
-40°C...+400°C
(-40°F...+752°F)
100 mbar...40 bar
(1.5psi...600 psi)
316L, AlloyC,
Tantal, Monel
PTFE, Gold
316L, AlloyC,
Tantal,
Monel
PTFE
Gold
100 mbar...40 bar
(1.5 psi...600 psi)
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Installation Type | Inline |
| Fluid Type | gas |
| Line Size Range | 450-6527 |
| Display Type | Handheld |
| Output Signal | 4–20 mA |
| Accuracy | ±0.5% |
| Mounting | Portable |
Additional Information:
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Prosonic |
| Meter Technology | Ultrasonic |
| Fluid Type | liquids |
| Line Size | 50 mm |
| Output Signal | 4–20 mA |
| Accuracy | ±0.5% |
| Liner Material | PFA |
| Electrode Material | Tantalum |
| Communication | HART |
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200
0 to 15 m/s (0 to 50 ft/s)
–40 to +130 °C (–40 to +266 °F)
N/A
Additional Information:
Service Details:
| Series | Promag D |
| Meter Technology | Ultrasonic |
| Fluid Type | Gas |
| Output Signal | 4–20 mA |
| Accuracy | ±0.5% |
| Liner Material | Hard Rubber |
| Electrode Material | Stainless Steel |
| Communication | HART, FOUNDATION Fieldbus |
Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
ATEX: 2014/34/EU
EMC: 2014/30/EU
RoHS: 2011/65/EU
PED: 2014/68/EU
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | Proline Prosonic |
| Meter Technology | Ultrasonic |
| Fluid Type | Gas |
| Line Size | 50 mm |
| Output Signal | 4–20 mA |
| Accuracy | ±0.5% |
| Liner Material | PFA |
| Electrode Material | Tantalum |
| Communication | HART |
Additional Information:
Service Details:
| Series | Proline Prosonic |
| Meter Technology | Ultrasonic |
| Fluid Type | Gas |
| Line Size | 80 mm |
| Output Signal | HART, 4–20 mA |
| Accuracy | ±0.5% |
| Electrode Material | Tantalum |
| Communication | HART |
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.2 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.1 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±0.8 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r.
Gas: 0.3 m/s to 40 m/s
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell
0.7 to 101 bar a (10.15 to 1464.88 psi a)
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2
MID 004 accuracy class II (2%)
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
0 to 150° (17.8 to 302 °F)
PN 25/ ASME Cl. 150
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
Service Details:
| Minimum Order Quantity | 1 Piece |
| Series | flowmeter |
| Meter Technology | Ultrasonic |
| Fluid Type | Gas |
| Line Size | 8_ 36 |
| Accuracy | ±0.2% |
| Liner Material | Hard Rubber |
| Electrode Material | Stainless Steel |
| Communication | Modbus TCP |
Volume a. c., volumetric flow a. c., Fluid velocity, Speed of sound
LNG (Liquefied Natural Gas)
8 ″ ... 36 ″
DN200 ... DN900, Schedule 40S/STD acc. ASME B36.19 / B36.10, others on request
Additional Information: